DA1
0 kg
|
12 Volt Door Monitor Unit
Housed in a sloping front wall or desk mount ABS box, with sounder ON/OFF keyswitch. The unit uses a closed loop which, when opened, can sound immediately or after a set duration. In alarm state there are a set of clean contacts available. The sounder can be reset via keyswitch, or non-latched and reset by closing the loop.
|
|
|
DA1/DG
0 kg
|
12 Volt Door Monitor Unit
Housed in a dual gang wall mount ABS box, with sounder ON/OFF keyswitch. The unit uses a closed loop which, when opened, can sound immediately or after a set duration. In alarm state there are a set of clean contacts available. The sounder can be latched and reset via keyswitch, or non-latched and reset by closing the loop.
|
|
|
DA1/DGM
0 kg
|
12 Volt Door Access Monitor Unit
As DA1/DG with mild steel front plate in dual gang mounting box.
|
|
|
DA1/SB
0 kg
|
240 Volt Door Monitor Unit
Housed in a sloping front wall or desk mount ABS box, with sounder ON/OFF keyswitch. The unit uses a closed loop which, when opened, can sound immediately or after as set duration. In alarm state there are a set of clean contacts available. The sounder can be latched and reset via keyswitch, or non-latched and reset by closing the loop.
|
|
|
DCIF
0 kg
|
Door Interface Control
Interface control with 6 hall affect inputs, twin lock relays, 6 door contact inputs, 3 cc push to exit inputs, 1 break glass input, global control input, separate door control output, door open alarm output, 4 status outputs, door LED status output, separate keyswitch control and 8 LED indications. Available boxed or PCB only, please call for more details.
|
|
|
DIC2
0 kg
 Spec Sheet
|
Door Interlock Control
PCB is designed as a 2 door interlock which can be expanded to multi door interlocking. When any one function is activated all other functions are locked out. Each door release time range is from 5 to 90 seconds in 7 steps. Provision is made for egress button on a single door on follow through interlocking. Please contact us for a full spec sheet.
|
|
|
DIC2BX
0 kg
|
Door Interface Control
2 Zone door control unit, as DIC2, housed in 310 x 230 x 50mm mild steel box with hinged lid.
|
|
|
DIC4
0 kg
|
Door Interlock Control
4 door interlock which can be expanded to multi door interlocking. When any one function is activated all other functions are locked out. Each door release time range is from 5 to 90 seconds in 7 steps. Provision is made for egress button on a single door on follow through interlocking. Please contact us for a full spec sheet. Enclosed in 310 x 310 x 50mm mild steel enclosure, optional screen printing available.
|
|
|
Door Forced 3
0 kg
|
Programmable door force monitor
used for monitoring magnalocks and access control doors.
|
|
|
K1SP
0 kg
|
DPDT Keyswitch
Mounted on single gang plate, fitted with common key as standard.
|
|
|
NEWK
0.35 kg
|
Newmark lock interface board
A small PCB only 50mm x 50mm with 12 or 24 volt DC supply line to switch an 8 amp power relay from a 5 volt output in Newmark lock control. 12/24 volt selector is an on-board jumper. Input trigger and relay activation or LED indicated.
|
|
|
Strobe2
0 kg
 Spec Sheet
|
Strobe/Sounder unit
This unit can be supplied in either 12 or 24 volt DC versions. Housed in a double gang box with high output programmable sounder (with 24 available sounds), front mounted low profile blue strobe light and an ON/OFF keyswitch. Red, yellow and white strobes are available as an option. Inside the box is a PCB with 2 normally closed loops, outputs for strobe/sounder and clean change over relay contacts. On opening the closed loops the unit can be set to alarm immediately or after a set time, controlled by on-board preset. It can be also configured to latch and reset via the keyswitch or auto reset by closing the loop. If alarm is set to delay then re-closing the loop before alarm condition is triggered will reset the unit.
|
|
|
Sounder Unit
0 kg
 Spec Sheet
|
Sounder Unit
As STROBE 2, without strobe fitted.
|
|
|
Strobe2 ST
0 kg
 Spec Sheet
|
Strobe/Sounder unit
As STROBE2 but fitted in 2 piece steel box, finished in white. 90mm x 48mm x 180mm approx. Strobe height is 35mm.
|
|
|
Strobe2A
0 kg
|
Strobe2A
Replacement PCB for STROBE2.
|
|
|
Strobe2B
2 kg
|
Strobe/Sounder unit
with 1 amp PSU.
|
|
|
Strobe2C
2 kg
|
Strobe/Sounder unit
with 2 amp PSU.
|
|
|
PET
0 kg
|
'Push to Exit'
High impact 35mm domed green press switch mounted in a single gang plate. Engraved with 'Press to Exit', switch contacts are rated at 250v AC 10 amp (resistive) load. Optionally available with black, 46mm blue pull to reset, red round or black, red, or green square.
|
|
|
PET/SS
0 kg
|
Push to exit button
As PET but with stainless steel mounting plate.
|
|
|
PET/BR
0 kg
|
Push to exit button
As PET but with brass mounting plate.
|
|
|
PET/BB
0 kg
|
Back box
for push to exit button.
|
|
|
PET/2LED
0 kg
|
Push to exit button
with 2 LEDs, red and green, for lock status indication.
|
|
|
K1HS
0 kg
|
High Security Keyswitch
box with Kaba keyswitch, 2 status LEDs, back tamper and audio. Key registration biased 2 position key. Also available from KT Manufacturing.
|
|
|
K2HS
0 kg
|
High Security Keyswitch
box with Yale keyswitch, LED status indication, back tamper, key registration and biased 2 position key.
|
|
|
K3HS
0 kg
|
Medium Security Keyswitch
3 keyswitch type, key removal on position, key removal 2 position and key removal centre position. Includes LED status indciation.
|
|
|
DISABLE
0 kg
|
Disabled toilet alarm
on a 2 gang switch plate for flush or surface mounting. The unit has a 24 volt supply line input with clean contact and assurance 1 amp output. The front plate has a disabled logo with a 20mm LED, sounder, mute and reset switch. Start input is from a normally open switch which, when activated, starts the LED flashing, the sounder and changes the relays contact state. The sounder can be muted which will make the LED become steady. When the call switch is returned to normal the unit can be reset.
|
|
|
KTC 1 Zone PCB
0 kg
|
1 Zone PCB
Open or closed circuit activation with mute and reset, LED output which flashes until muted and clean changeover contacts rated at 1 amp. Also has sounder output (100mA rated), lamp test and zone isolation. Multiple zone cards can be connected together.
|
|
|
KTC 2 Zone PCB
0 kg
|
2 Zone PCB
Open or closed circuit activation with mute and reset, LED output which flashes until muted and clean changeover contacts rated at 1 amp. Also has sounder output (100mA rated), lamp test and zone isolation. Multiple zone cards can be connected together.
|
|
|
KTC 4 Zone PCB
0 kg
|
4 Zone PCB
Open or closed circuit activation with mute and reset, LED output which flashes until muted and clean changeover contacts rated at 1 amp. Also has sounder output (100mA rated), lamp test and zone isolation. Multiple zone cards can be connected together.
|
|
|
KTC 6 Zone PCB
0 kg
|
6 Zone PCB
Open or closed circuit activation with mute and reset, LED output which flashes until muted and clean changeover contacts rated at 1 amp. Also has sounder output (100mA rated), lamp test and zone isolation. Multiple zone cards can be connected together.
|
|
|